An experimental work on radiation scattering features of some thermoluminescent dosimetry materials


YILMAZ D., AKKUŞ T.

Radiation Physics and Chemistry, cilt.216, 2024 (SCI-Expanded) identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 216
  • Basım Tarihi: 2024
  • Doi Numarası: 10.1016/j.radphyschem.2023.111456
  • Dergi Adı: Radiation Physics and Chemistry
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, Aerospace Database, Chemical Abstracts Core, Chimica, Communication Abstracts, Compendex, INSPEC, Metadex, Pollution Abstracts, Civil Engineering Abstracts
  • Anahtar Kelimeler: Albedo parameters, Coherent scattering, Compton scattering, Effective atomic number, Kerma, Thermoluminescent dosimetry material
  • Erzincan Binali Yıldırım Üniversitesi Adresli: Evet

Özet

In this study, albedo parameters are experimentally measured to determine radiation scattering features of some thermoluminescent dosimetry materials (TLD 100, TLD 100h, TLD 200 and TLD 400). In experimental setup, it was used scattering angle of 168°, 59.54 keV gamma rays and HPGe detector. The effective atomic numbers of the investigated materials were determined from the coherent to Compton scattering intensity ratio. Also, the mass attenuation coefficient, the mass energy absorption coefficient and kerma relative to air and ICRU tissue were calculated for the TLD materials. It was observed that TLD 100h is the best tissue equivalent material among other TLD materials and best reflects 59.54 keV gamma rays.