Correlation of Diffusion weighted MR Imaging and ADC Values of Hepatic Metastasis of Gastrointestinal Stromal and Gastroenteropancreatic Neuroendocrine Tumors


Aydın H., Metin M. R., KIZILGÖZ V.

Current Medical Imaging, cilt.20, 2024 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 20
  • Basım Tarihi: 2024
  • Doi Numarası: 10.2174/1573405620666230522151427
  • Dergi Adı: Current Medical Imaging
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Biotechnology Research Abstracts, EMBASE, MEDLINE
  • Anahtar Kelimeler: Diffusion, GIST, Hepatic, Imaging, Metastasis, MR
  • Erzincan Binali Yıldırım Üniversitesi Adresli: Evet

Özet

Background: DWI and ADC-mapping was performed to analyze hepatic metastasis of GIST, GEP-NET. Objective: The objective of this study is to present hepatic metastasis of GIST and GEP-NET with Diffusion weighted MR imaging(DWI) and the Apparent diffusion coefficients (ADC) values of masses. Methods: 18 GIST patients and 8 GEP-NET patients were examined retrospectively. 11 males and 6 females were present in GIST group, 7 males to 5 females were involved in GEP-NET group. 18 primary GIST and 10 hepatic metastasis of GIST, 8 original GEP-NET and 19 hepatic metastasis of GEP-NET; total 55 GIST and GEP-NET masses were analysed by ADC mapping. MR images were acquired by 1,5 T MR units (32 mT/min gradient strength-Achieva; Philips Healthcare, Best, Netherlands and 32 channel GE Signa GE-Wisconsin-USA); by using a 4-8 channel standard phased-array torso XL coil, all images were evaluated by an Abdominal MRI experienced radiologist. DWI was performed in the transverse plane by using spin-echo-planar imaging sequence. Results: No statistical differences were observed between GIST and GEP-NET patients according to age and gender variations. No significant statistical differences were observed according to the diameters and ADC values of GIST and GEP-NET patients. A significant statistical difference was observed between GIST and GEP-NET groups in terms of size of liver metastasis which was significantly higher in GIST patients. All three groups (GIST_Hep. MET, GEP-NET_Liver_Met and normal) were statistically differed according to ADC values. With the ROC curve analysis: Hepatic metastasis of GIST(n=10) and normal liver (n:47) had cut-off value for ADC: 0.925 under AUC: 0.939 with regard to ADC values and regarded 89.4% Sensitivity, 100% Specificity, 100% PPV and 66.7% PPV. ROC curve of GEP NET_ Hepatic metastasis (n=19) group and normal liver (n:47) group presented cut-off value for ADC: 0.860 under AUC: 0.967 correlated to ADC values with 93.6% sensitivity, 89.5% specificity, 95.7% PPV and 85% PPV. Conclusion: High cellular tumors resulted from liver metastasis of GIST and GEP-NET’s, and a positive correlation was observed between ADC values and cellularity/differentiation ratios of metastatic masses.